As of its 2.0 release, DAQami now supports Windows 10. However there is a known issue in which DAQami will stop working. We found that some USB DAQ devices, if plugged in before the computer is booted or rebooted, will fail to start up properly. Then starting DAQami will result in it hanging. To recover from the hang, either reboot or end the DAQami.exe process via the task manager
At this time the workaround is to reset the DAQ device, directly after booting or rebooting your PC, by temporarily removing the USB connection. Once this has be done, DAQami will work correctly. This issue will be rectified as part of InstaCal/UL 6.51 due out later in 2015. The following list of devices are known to have the problem:
USB-1208HS
USB-1208HS-2Ao
USB-1208HS-4AO
USB-1608G
USB-1608GX
USB-1608GX-2AO
USB-2020
USB-DIO32HS
USB-CTR04
USB-CTR08
USB-2623
USB-2627
USB-2633
USB-2637