clear; clc;
%%
mcAssembly = NET.addAssembly('DAQFlex');
%% get list of the attached daq devices
mcArgument = MeasurementComputing.DAQFlex.DeviceNameFormat.NameAndSerno;
mcDevices = MeasurementComputing.DAQFlex.DaqDeviceManager.GetDeviceNames(mcArgument);
%% Choose First Device, and create a DaqDevice object for it
mcDeviceString = mcDevices(1);
mcDevice = MeasurementComputing.DAQFlex.DaqDeviceManager.CreateDevice(mcDeviceString);
try
%set first channel
mcDevice.SendMessage('AISCAN:LOWCHAN=0').ToString();
%set last channel
mcDevice.SendMessage('AISCAN:HIGHCHAN=0').ToString();
%set sample rate in hertz
mcDevice.SendMessage('AISCAN:RATE=5000').ToString();
rate=5000; %use to scale display
%enable data conversion to volts
mcDevice.SendMessage('AISCAN:SCALE=ENABLE').ToString();
%set acquisition to run continously
mcDevice.SendMessage('AISCAN:SAMPLES=0').ToString();
%set the input range to +/- 5 volts
mcDevice.SendMessage('AISCAN:RANGE=BIP5V').ToString();
range = 5.0;
%begin acquisiton
mcDevice.SendMessage('AISCAN:START').ToString();
fprintf('Acquisition Start\n');
%get the number of samples acquired so far
Count = char(mcDevice.SendMessage('?AISCAN:COUNT').ToString());
%parse the string
ct = strsplit(Count,'=');
%convert the number string to number
CurrentCount = str2num(ct{2});
%desiredCount is the amount I want to read on each iteration
blocksize = 256;
tm = blocksize/rate; %time to acquire blocksize
%create window for displaying plots
h = figure;
x = transpose((0:blocksize-1) * 1 / rate);
myCount = 0;
%The acquisition is set to continuously acquire data
%however for example purpose stop after 50000 reading
while myCount < 50000
%need to add sleep or pause so that DaqFlex can update the count
%variable
pause(tm);
%read the device and put the data into an array
DataArray = transpose(double(mcDevice.ReadScanData(blocksize,10000)));
myCount = myCount + blocksize;
%plot the data
plot(x(1:blocksize),DataArray(1:blocksize));
axis([0.0 (blocksize * 1/rate) -range range ]);
title('Voltage Waveform');
xlabel('Time');
ylabel('Volts');
Count = char(mcDevice.SendMessage('?AISCAN:COUNT').ToString());
ct = strsplit(Count,'=');
CurrentCount = str2num(ct{2});
end
fprintf('\nTotal number read %d\n', myCount)
catch err
getReport(err,'basic')
mcDevice.SendMessage('AISCAN:STOP').ToString()
MeasurementComputing.DAQFlex.DaqDeviceManager.ReleaseDevice(mcDevice)
break
end
fprintf('\nAcquisition Stop\n');
mcDevice.SendMessage('AISCAN:STOP').ToString();
MeasurementComputing.DAQFlex.DaqDeviceManager.ReleaseDevice(mcDevice)