Measurement Computing   Easy to Use | Easy to Integrate | Easy to Support catalog banner

NI LabVIEW Temperature measurement for USB-2416 & USB-2408

Expand / Collapse
 

NI LabVIEW Temperature measurement for USB-2416 & USB-2408


The ULx temperature example [ULx Acq Temperature Sample] wants to see channels that begin with T for temperature - for example, Dev0/Ti0 for channel 0 temperature. However, when MCC made the USB-2416 and USB-2408 they decided to make the channels begin with A for analog even though it can measure temperature. As a result the ULx Acq Temperature Sample program does not work for these devices. To support customers better this article supplies an example specifically for the USB-2416 and because the USB-2408 is a mini version of the USB-2416 it works for it too.Attached to this article is a simple example that reads four thermocouples. The example can be used to measure both voltage and temperature - just change the channel type in InstaCal. 







Rate this Article:

Attachments


USB-2408TCandVolts_LV85.llb USB-2408TCandVolts_LV85.llb (28.84 KB, 1,434 views)